Open navigationDensioHomeToolsClass chartMethodologySources
Freight class 60
Class 60 covers 30 up to 35 lb/ft³. This is the one band whose previous wording was never captured, and the changelog says so instead of guessing.
Density class per NMFC Docket NMFC-2025-1 (NMFTA Disposition Bulletin 1371), effective 2025-07-19.
Density scale: 13 subprovisions, class 50–400. Subject to NMFC Item (Rule) 170.
Where this band sits on the scale
1246810121522.5303550
The outlined band is the one this page is about; the ticks are the density bounds it sits between. The last band is open at the top, so the axis ends without a boundary.
NMFC 13-subprovision density scale. Intervals are half-open: each subprovision includes
its lower density and excludes its upper density, and the wording below is the published
wording. The first band is open at the bottom and the last band is open at the top.
Class 60 is subprovision 11 of 13 in the current scale, and NMFTA's published wording for it is "30 but less than 35".
The band one step lighter is class 65 (22.50 ≤ density < 30.00 lb/ft³). The band one step denser is class 55 (35.00 ≤ density < 50.00 lb/ft³).
It spans 5.00 lb/ft³, wider than 7 of the other 10 bounded bands in the scale.
In a handling unit measuring 40 × 48 × 48 in — about 53.33 ft³, an illustrative size rather than a standard pallet specification — class 60 covers shipments weighing 1600.00 lb or more but less than 1866.67 lb.
Class 60 covers freight from 30 lb/ft³ up to but not including 35 lb/ft³. It is the lowest of the three bands at the top of the scale, and it is also the one row in this site's change record where the previous wording was not captured — the changelog marks it as not recorded rather than filling it in.
The one row the change record does not contain
When the scale was expanded from 11 subprovisions to 13, the upper end of this band changed shape. The current wording stops at 35 and the two added bands begin there, so whether the superseded table's top band read 30 or greater is consistent with an eleven-row table — but it was never captured while it was still published.
Rather than reconstruct it, the changelog records the gap and says why. A reconstructed old value that happens to be right is indistinguishable from one that happens to be wrong, and a change record that quietly guesses is worth less than one that admits a hole.
Frequently asked
Why is one row in the changelog marked as not recorded?
Because the superseded wording was never captured. NMFTA publishes only its most recent docket on the public docket page, so the eleven-subprovision table was replaced before its exact top band was written down.
Does the missing record affect the class value for this band?
No. Class 60 for 30 up to 35 lb/ft³ comes from the current published scale and is verified against the primary source. What is missing is the previous wording, which affects the change history rather than the calculation.
Related
Freight class 65The 22.5-to-30 lb/ft³ band, starting on a fractional boundary.
Freight class 55The widest band in the scale: 35 to 50 lb/ft³, added in 2025.